Isolation transformers

Joint Features of isolation transformers

Joint Features of our isolation transformers

The isolation transformer is a transformer used to isolating the powered device from the power source, usually for safety reasons. Isolation transformers provide galvanic isolation and are used to protect against electric shock, to suppress electrical noise in sensitive devices, or to transfer power between two circuits which must not be connected. 
Isolation transformers block transmission of the DC component in signals from one circuit to the other, but allow AC components in signals to pass.

Our transformers have a ratio of 1 to 1 between the primary and secondary windings. They are often used to protect secondary circuits and individuals from electrical shocks between energized conductors and earth ground. Typical using is galvanical separation of oscilloscope or sensitive medical apparatus from the mains.

Joint features of construction 

Transformer is equally designed for
permanent supply of maximal output to the workload. Electronics are placed in rugged metal chassis with Comaxit surface.

 

Isolation transformer

OT230.012

Output voltage 230 V / 50 Hz.

Output current up to 1.2 A.

Sine waveform of output voltage.

Separate input and output voltage.

Illuminated switch.

Carrying handle.

Robust metal chassis.

Sufficiently dimensioned transformer for continuous power supply.

Power voltage:
Output voltage:
Output current:
Output frequency:
Output voltage stability:
Output frequency stability:
Galvanically isolated output:
Mains fuse:
Output fuse:
Lead wire length:
Color:
Dimensions (h, w, d - approx.):
Weight approx:
Warranty:

230 V / 50 Hz
230 V
1,2 A
50 Hz
according to network stability
according to network stability
YES
T 250V / 2.0A
T 250 V / 1.25 A
2. m
black
172 x 244 x 282mm
9.2 kg
24 months

Isolation transformer

OT230.021

Output voltage 230 V / 50 Hz

Output current up to 2.1 A

Sine waveform of output voltage

Separate input and output voltage

Illuminated switch

Carrying handle

Robust metal chassis

Sufficiently dimensioned transformer for continuous power supply

Power voltage:
Output voltage:
Output current:
Output frequency:
Output voltage stability:
Output frequency stability:
Galvanically isolated output:
Mains fuse:
Output fuse:
Lead wire length:
Color:
Dimensions (h, w, d - approx.):
Weight approx:
Warranty:

230 V / 50 Hz
230 V
2,1 A
50 Hz
according to network stability
according to network stability
YES
T 250 V / 3.15 A
T 250 V / 2.25 A
2 m
black
172 x 244 x 282mm
9.2 kg
24 months

Isolation transformer

OT230.030

Output voltage 230 V / 50 Hz

Output current up to 3.0 A

Sine waveform of output voltage

Separate input and output voltage

Illuminated switch

Carrying handle

Robust metal chassis

Sufficiently dimensioned transformer for continuous power supply

Power voltage:
Output voltage:
Output current:
Output frequency:
Output voltage stability:
Output frequency stability:
Galvanically isolated output:
Mains fuse:
Output fuse:
Lead wire length:
Color:
Dimensions (h, w, d - approx.):
Weight approx:
Warranty:

230 V / 50 Hz
230 V
3 A
50 Hz
according to network stability
according to network stability
YES
T 250V / 4A
T 250V / 2A
2 m
black
172 x 244 x 282mm
10.9 kg
24 months

Isolation transformer

OT230.050

Output voltage 230 V / 50 Hz

Output current up to 5.0 A

Sine waveform of output voltage

Separate input and output voltage

Illuminated switch

Carrying handle

Robust metal chassis

Sufficiently dimensioned transformer for continuous power supply

Power voltage:
Output voltage:
Output current:
Output frequency:
Output voltage stability:
Output frequency stability:
Galvanically isolated output:
Mains fuse:
Output fuse:
Lead wire length:
Color:
Dimensions (h, w, d - approx.):
Weight approx:
Warranty:

230 V / 50 Hz
230 V
5 A
50 Hz
according to network stability
according to network stability
YES
T 250V / 4A
T 250V / 2A
2 m
black
172 x 244 x 282mm
16.7 kg
24 months

Isolation transformer

OT230.100

Output voltage 230 V / 50 Hz

Output current up to 10 A

Sine waveform of output voltage

Separate input and output voltage

Illuminated switch

Carrying handle

Robust metal chassis

Sufficiently dimensioned transformer for continuous power supply

Power voltage:
Output voltage:
Output current:
Output frequency:
Output voltage stability:
Output frequency stability:
Galvanically isolated output:
Mains fuse:
Output fuse:
Lead wire length:
Color:
Dimensions (h, w, d - approx.):
Weight approx:
Warranty:

230 V / 50 Hz
230 V
10 A
50 Hz
according to network stability
according to network stability
YES
T 250 V / 12.5 A
F 250V / 10A
2 m
black
172 x 244 x 282mm
approx. 26.5 kg
24 months

Isolation transformer

OT230.200

Output voltage 230 V / 50 Hz

Output current up to 20 A

Sine waveform of output voltage

Separate input and output voltage

Illuminated switch

Carrying handles

Robust metal chassis

Sufficiently dimensioned transformer for continuous power supply

Power voltage:
Output voltage:
Output current:
Output frequency:
Output voltage stability:
Output frequency stability:
Galvanically isolated output:
Mains fuse:
Output fuse:
Lead wire length:
Color:
Dimensions (h, w, d - approx.):
Weight approx:
Warranty:

230 V / 50 Hz
230 V
20 A
50 Hz
according to network stability
according to network stability
YES
circuit breaker B 20 A
circuit breaker B 20 A
1 m
black
280 x 250 x 360mm
approx. 44 kg
24 months

©2019 by Diametral         Privacy policy (GDPR)